Author: Mark Yeager – Integrated Test & Measurement (ITM), LLC
Industry: Power Generation
Software: iTestSystem
NI Products Used: NI cDAQ-9189, NI 9234, NI 9229
iTestSystem and NI CompactDAQ for Structural Validation and Testing of Generator Sets
The Challenge
Building a reliable system to test Generator Set vibration levels after production in order to verify that the units were designed and assembled properly.
“The flexibility and quality of the NI CompactDAQ platform combined with the productivity of iTestSystem software allowed us to build a custom and high-performance test system in a short amount of time, saving us and our customer substantial costs.” – Mark Yeager, Integrated Test & Measurement (itm), LLC
The Solution
For our solution, we developed and installed a data collection system that would acquire, analyze and report the vibration levels recorded at 20 locations around the Generator Set structure. We used a National Instruments (NI) CompactDAQ Ethernet chassis (cDAQ-9189) with 8 dynamic signal acquisition (DSA) input modules, NI 9234 and NI 9229, to condition, synchronize and digitize the acceleration and voltage signals.
The NI 9234 module was connected to accelerometers for collecting accurate high-speed vibration measurements. The NI 9229 module was connected to a magnetic pickup sensor to determine the rotational speed of the generator. We chose the NI 9229 module because it combined a high resolution with a wide voltage range, and was able to be synchronized with the NI 9234 module. We chose the NI cDAQ-9189 Ethernet chassis with Ethernet connectivity because the test cells had an existing Ethernet network. We used our configuration based data acquisition and analysis iTestSystem software, which was built using NI LabVIEW system design software, to acquire and view the vibration data generated by NI cDAQ hardware. We also created a custom plug-in for iTestSystem that generated vibration reports and animated vibration modes.
Creating a Flexible, High-Performance Test System with iTestSystem and CompactDAQ
Our customer needed a reliable system to test the vibration levels of its Generator Sets prior to field deployment so they could validate their design and manufacturing. They also wanted the test system to record synchronized, high-speed data that could be used by engineers to troubleshoot structural problems if they occurred. By leveraging integrated hardware from NI, we were able to provide our customer with a solution that enabled their test cell technicians to measure structural vibration levels safely, quickly and efficiently. They are now identifying and fixing structural flaws of their generator sets earlier in the process to create higher quality products for their customers. The flexibility and quality of the NI CompactDAQ platform combined with iTestSystem allowed us to build a custom and high- performance test system for this customer in a short amount of time, saving us and our customer substantial costs.
Plans on Transitioning from NI CompactDAQ to stand-alone NI CompactDAQ
We’ve used USB and Ethernet-based NI CompactDAQ systems and our iTestSystem software, based on NI LabVIEW, for years to build high-performance data acquisition and test systems for our customers in the power generation, off-highway, rail and in-vehicle markets. Since these applications require a more portable solution with built-in data logging features, stand-alone NI CompactDAQ systems will provide us with more logging and processing capabilities within the CompactDAQ platform. Additionally, since the NI cDAQ-913x systems can be used with our NI LabVIEW-based iTestSystem software, the NI DAQmx driver and 50+ existing NI C Series modules, we’ll be able to convert our existing Ethernet CompactDAQ system to stand-alone NI CompactDAQ systems with very little effort.
The Advantage of a ITM’s Solution
Our solution enabled our customer to quickly determine if their Generator Sets had failed their designed vibration criteria. If a failure had occurred, engineers could then use the same synchronized vibration data to quickly identify structural problems and proactively adjust the design to remedy flaws prior to deployment to the end customer. By catching these structural dynamics problems in the factory and not in the field, our customer has realized a substantial cost savings because of the reduced time and expenses associated with similar field validation tests.
Author Information: For more information on this Case Study, iTestSystem, Generator Test Hardware or other data logging solutions contact: Mark Yeager – Integrated Test & Measurement (itm), LLC – mark.yeager@iTestSystem.com